HB、HBS型防爆钢丝绳电动葫芦
HBD0.5-10t range of flame-proof wire electric hoist |
1.概述
HB、HBS型防爆钢丝绳电动葫芦符合JB/T10222-2001《防爆钢丝绳电动葫芦》的规定,电动葫芦可单独或配套安装在单梁超重机上使用,其主体可悬挂在工字钢轨道上作直线或曲线运行;固定式葫芦可安装在固定架上使用。
本系列电动葫芦的防爆性能符合GB3836.1-2000《爆炸性气体环境用电气设备 第1部分:通用要求》和GB3836.2-2000《爆炸性气体环境用电气设备 第2部分:隔爆型"d"》、GB3836.3-2000《爆炸性气体环境用电气设备 第3部分:增安型"e"》的规定,防爆标志ExdeIIBT4、ExdeIICT4,适用于工厂IIB、IIC级,温度级别T1-T4组的爆炸性气体环境。
2.结构型式有:D型:电动小车式,可单独或配套在单粱起重机上使用,A型:固定式,无运行机构,用底脚安装,按出绳方向可分A1、A2、 A3、A4四种, AB型:无运行结构,用架板孔安装在固定架上使用。
3.使用条件为:
海拔不超过1000m
环境空气温度不超过一20℃~40℃
环境空气相对湿度不超过90% (+25℃)
户内使用(腐蚀环境和户外场所,需特殊订购)
额定工作循环周期为10分钟,负载持续率Fc为25%,每小时的等效起动次数不超过120次。
电动葫芦主电路的额定电压为交流380V,频率50Hz,控制电压为36V。?
电动葫芦的品种规格及主要技术参数和外形尺寸详见产品样本介绍 |
|
1. General
HBD flame-proof wire electric hoists is on the leading level of the samekind of products which have the advantages of construction compact, volume small, hoisting weigh large, flame-proof construction advanced, safety and reliability high and maintenace convinient.
The explosion-proof characteristic which conforms to GB3836.1-2000 < <General Requirements- - Electrical Apparatus Used in ExplosiveAtmosphere Part 1 >> and GB3836.2-2000 << Flame-proof "d"-- ElectricalApparatus Used in Explosive Atmosphere Part 2 >> can be made into flame-proof type of dIIBT4 and dIICT4. This range of motors, can used inplaces where there are explosive gas mixture in factory. The main bodycan hang on the I-steel rail for straight or curve run, or be mountedat a fixed bracket for hoisting weight.
2. Operation condition?
Elevation above sea level: less than 1,000m.
Environment temperature:-20-40℃.
Relative huminity:less than 85%(+25℃).
Duty type is S4 whose the basic load continuity is 25% and theequivalent starting times is 120 every hour.
Rated voltage: 380V, while control circuit 380V or 660V.
Rated frequency: 50Hz.
Note: The hoist is used indoors.( if used in outdoor or corrosive places, the hoist must be ordered specially.)
The main parameters are as follows. |